Atomic Absorption Spectrophotometer - WFX-320 AAS Spectrometer
WFX-320 AAS Spectrometer
Atomic Absorption Spectrophotometer
Features
| Specifications WFX-320 AAS Spectrometer |
|---|
Main Specification of
| Wavelength range |
190-900nm |
|---|---|---|
Wavelength accuracy |
±0.5nm |
|
Resolution |
Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. |
|
Baseline stability |
0.005A/30min |
|
Background correction |
The D2 lamp background correction capability at 1A is better than 30 times. |
|
Light Source System |
Lamp number |
2 lamps (one preheating) |
Lamp current adjustment |
Micro-computer control
Adjustment range: 0~20mA, |
|
Lamp power supply mode |
Powered by square pulses |
|
Optical System |
Monochomator |
Single beam, Czerny-Turner design grating monochromator |
Grating |
1800 l/mm |
|
Focal length |
277mm |
|
Blazed Wavelength |
250nm |
|
Spectral Bandwidth |
0.1nm, 0.2nm, 0.4nm, 1.2nm |
|
Detection and Data Processing System |
Detector |
Photomultiplier with high sensitivity and wide spectral range. |
Electronic and micro-computer system |
Light energy and negative high-voltage auto-balance |
|
Display mode |
LED display of energy and measurement values, concentration direct reading |
|
Read mode |
transient, integral, peak height, peak area.
Integral or sampling time is in the range of 0.1-19.9s. |
|
Scale expansion |
0.1~99 |
|
Data processing mode |
Automatic calculation of mean, standard deviation and relative standard deviation. Repeating number is in the rang of 1-99 |
|
Measurement mode |
3~7 standards can be determined for curve fitting. Sensitivity correction available. |
|
Result printing |
Measurement data, working curve, signal profile and analytical conditions can all be printed out. |
|
Instrument self-check |
Check current status of each function key |
|
Flame Analysis |
Burner |
10cm single slot all-titanium burner |
Spray chamber |
All-plastic spray chamber. |
|
Nebulizer |
High efficiency glass nebulizer with metal sleeve. |
|
Position adjustment |
Adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner. |
|
Gas line protection |
Fuel gas leak alarm |
|
Characteristic Concentration and Detection Limit |
Air-C2H2 flame |
Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L; |
Function Expansion |
Flameless analysis with WF-1C graphite furnace system available. |
|
Hydride vapor generator can be connected for hydride analysis. |
||
Dimensions and Weight |
1020 x 490 x 540 mm, 80kg unpacked |
|
For further information or to place an order for the Atomic Absorption Spectrophotometer - WFX-320 AAS Spectrometer, please CLICK HERE, call us Toll-Free at: 1.877.884.TEST, or click on the "HOW TO ORDER" Button